Difference between revisions of "Equipment"
(→Characterization) |
(→1550 nm) |
||
(124 intermediate revisions by 13 users not shown) | |||
Line 1: | Line 1: | ||
+ | [[Equipment wish list]] | ||
+ | |||
+ | Equipment that has been checked out of the lab: [[Media:Check_out_list.doc|doc]]. | ||
+ | |||
+ | Equipment that is stored in the trailer: [[Media:Equipment_in_trailer_updated_05-31-2013_by_Stanton.docx|Equipment_in_trailer]]. Updated 03/04/13 | ||
+ | |||
+ | Equipment that is stored in the third floor office. Check here for spare computer parts: [[Media:Equipment_upstairsoffice.docx|docx]]. | ||
+ | |||
= Electrical = | = Electrical = | ||
== Microwave == | == Microwave == | ||
− | === | + | |
− | + | === Electrical spectrum analyzers === | |
− | + | ||
− | + | * [[Rohde & Schwarz FSU]] | |
− | * RF signal generators | + | |
− | + | * [[Agilent E4407B]] | |
− | ** [[Rohde & Schwarz SMB 100A]] (2) | + | |
− | + | * [[HP 70000]] (2) - these have an optical input port as well. They need to be installed in a mainframe. | |
− | + | ||
− | * Network analyzers | + | === RF signal generators === |
+ | |||
+ | * [[Agilent E8257D]] | ||
+ | |||
+ | * [[Agilent 8673D]] | ||
+ | |||
+ | * [[Rohde & Schwarz SMB 100A]] (2) | ||
+ | |||
+ | * [[Rohde & Schwarz SMF 100A]] | ||
+ | |||
+ | * [[Fluke 6060]] (2) | ||
+ | |||
+ | * HP 8340B synthesized sweep generator (10 MHz to 26.5 GHz) | ||
+ | |||
+ | === Data Tx/Rx === | ||
+ | |||
+ | *[[Quantum DDI|Quantum DD1]] divider delay unit | ||
+ | |||
+ | === Amplifiers === | ||
+ | |||
+ | * [[HP 8349B]] (2-20GHz) | ||
+ | |||
+ | * [[EIN 300L]] (kHz-110MHz) | ||
+ | |||
+ | === Network analyzers === | ||
+ | |||
+ | * [[HP 8703A]] (lightwave component analyzer) | ||
+ | |||
+ | * [[Agilent E8364A]] (PNA with [[Agilent LCA N4373A|LCA attachment]]) | ||
+ | |||
+ | * [[PNA-X HP N52454A]] (10MHz - 50GHz) | ||
+ | |||
+ | * We also have an HP 8510A (45MHz - 26.5 GHz) that has been donated to the microwave teaching lab in HFH. | ||
+ | |||
+ | === RF Filters === | ||
+ | |||
+ | * Variety available from K&L Microwave, Inc. | ||
+ | |||
+ | * [[K&L 20 GHz EPHI]] | ||
+ | |||
+ | === RF Components === | ||
+ | |||
+ | * [[Mixers]] | ||
+ | |||
+ | * [[Phase Shifters]] | ||
+ | |||
+ | === C-V meters === | ||
+ | |||
+ | * [[HP 4284A]] | ||
+ | |||
+ | === Data acquisition and switching === | ||
+ | * [[Hameg_8123]] | ||
+ | * [[Agilent 34980A]] with microwave and general purpose switching modules | ||
+ | * [[Monochrome Image Capture Card]] | ||
=== Cables & connectors === | === Cables & connectors === | ||
+ | |||
+ | * See the attached [[Media:Connectors.docx|document]] for instructions on microwave connector care. | ||
+ | |||
+ | === Probes === | ||
+ | |||
+ | RF probes and their latest calibration files: | ||
+ | |||
+ | GSG 100: | ||
+ | |||
+ | * 40GHz S/N 96265: [[File:ACP40_GSG100_96265.txt]] | ||
+ | |||
+ | === Other === | ||
+ | |||
+ | * [[HP 70820A]] microwave transition analyzer (essentially an oscilloscope with excellent rise-time measuring capabilities) | ||
== DC == | == DC == | ||
=== Voltage/current sources === | === Voltage/current sources === | ||
+ | *[[Keithley 2400]] series source meters | ||
+ | |||
+ | *[[Keithley 2600]] series source meters | ||
+ | |||
+ | *[[ILX LDP 3811]] pulsed current source | ||
+ | |||
+ | *[[ILX LDX-3207B]] laser diode driver | ||
+ | |||
+ | *[[LDX-3220]] laser diode driver | ||
+ | |||
+ | *[[Light Control Instruments 502]] laser diode driver | ||
+ | |||
+ | *[[SDL-8610-D]] laser diode driver (for SDL-8610 850 nm [[SDL-8610|lasers]]) | ||
+ | |||
+ | *[[ILX FOA-8100]] fiber amplifier driver | ||
+ | |||
+ | *[[LCI-102]] current source | ||
+ | |||
+ | *[[New Focus 0901]] current source | ||
+ | |||
+ | *[[Agilent E3640]] DC voltage source | ||
+ | |||
+ | *[[HP 6205C]] dual DC voltage source | ||
+ | |||
+ | *[[Kikusui PAB 18-3]] DC voltage source | ||
+ | |||
+ | *[[Lambda LA-200]] DC voltage source | ||
+ | |||
+ | *[[LDC9003A]] DC voltage source | ||
+ | |||
+ | *[[Bertran 215]] High-voltage DC source | ||
+ | |||
=== Multimeters === | === Multimeters === | ||
+ | |||
+ | *[[HP 4338B]] milliohm-meter | ||
+ | |||
+ | *[[Keithley 6485]] picoammeter | ||
+ | |||
+ | *[[Keithley 485]] picoammeter | ||
+ | |||
+ | *[[Fluke 8012A]] multi-meter | ||
+ | |||
+ | *[[HP 3468B]] multi-meter | ||
+ | |||
+ | *[[HP 3478A]] multi-meter | ||
+ | |||
+ | *[[Keithley 175]] multi-meter | ||
+ | |||
+ | === Semiconductor parameter analyzers === | ||
+ | |||
+ | * [[HP 4145A]] Semiconductor parameter analyzer | ||
+ | |||
+ | |||
+ | === Temperature controllers === | ||
+ | *[[Oxford ITC503]] | ||
+ | |||
+ | *[[ILX LDT-5412]] | ||
+ | |||
+ | *[[ILX LDT-5948]] | ||
+ | |||
+ | *[[ILX LDT-5910]] | ||
+ | |||
+ | *[[Light Control Instruments 320]] | ||
+ | |||
+ | *[[Lightwave microsystems TC]] | ||
+ | |||
+ | *[[Lakeshore 805]] | ||
+ | |||
+ | |||
== AC == | == AC == | ||
=== Oscilloscopes === | === Oscilloscopes === | ||
+ | |||
+ | * [[HP 54503A]] | ||
+ | |||
+ | * [[Hitachi V-355]] oscilloscope | ||
+ | |||
+ | * [[Tek 11801]] digital sampling scope | ||
+ | |||
+ | * [[Tek 5104B]] oscilloscope | ||
+ | |||
+ | * [[Lecroy SDA 100G]] oscilloscope | ||
+ | |||
=== Pulse generators === | === Pulse generators === | ||
+ | *[[Agilent 33250A]] Function generator to 80MHz | ||
+ | *[[HP 8116A]] (2) function generators to 50MHz | ||
+ | |||
+ | *[[HP 214B]] | ||
+ | |||
+ | *[[PulseBlasterDDS]] (2) PCI board to generate pulses with 100MHz clock | ||
+ | |||
+ | === Lock-in amplifiers === | ||
+ | *[[EG&G 5210]] | ||
+ | |||
+ | *[[Stanford Research SR830 DSP]] | ||
+ | |||
+ | === Other amplifiers === | ||
+ | *[[SR570]] current pre-amplifier | ||
= Optical = | = Optical = | ||
+ | == OSAs == | ||
+ | * [[HP 70951A]] | ||
+ | |||
+ | * [[Agilent 86142B]] | ||
+ | |||
+ | * [[Yokogawa AQ6370C-1]] | ||
+ | |||
+ | * [[SPEX 500M]] | ||
+ | |||
== Fiber optics == | == Fiber optics == | ||
+ | === OADM Filter === | ||
+ | * [[OPLink OADMG2C34000214]] (>4) 1549.87~1550.37nm | ||
+ | === Tunable filters === | ||
+ | |||
+ | * [[JDSU TB4500]] (2) 1535-1565 nm, F-P type | ||
+ | |||
+ | * [[Koshin FC-1560B-1-1]] (1) 1540-1560 nm (2 filters, 1 housing) | ||
+ | |||
+ | * [[Santec OTF]] (4) 1535-1565 nm, various bandwidths, probably membrane | ||
+ | |||
+ | * [[Agiltron FOTF-023121333]] (1) 1270-1345 nm, 1nm 3dB bandwidth, IL = 2.1~2.8dB, probably membrane | ||
+ | |||
+ | === Isolators === | ||
+ | === Polarizers === | ||
+ | * [[OZopticsPolarizers]] Polarizers from OZ optics | ||
+ | |||
+ | === Polarization beam splitters === | ||
+ | * 9/125-SPP-1550-PBS-50-3A3U3U: from "ozoptics", one SMF in (APC)/two PMF (UPC) out; 50 dB reflection; | ||
+ | |||
+ | === Switches === | ||
+ | * [[HP 86060C]] lightwave switch | ||
+ | |||
+ | === Fiber Spools === | ||
+ | * [[Media:FiberSpoolsOTDR.zip]] | ||
== Detectors == | == Detectors == | ||
+ | ===High-speed Measurement=== | ||
+ | * [[Agilent LCA N4373A]] Lightwave component analyzer (DC - 67 GHz) - attached to the [[Agilent E8364A]] | ||
+ | |||
+ | * [[Agilent LCA xxx]] Lightwave component analyzer (DC - 26.5GHz) | ||
+ | |||
+ | === Power meters/broad area PDs === | ||
+ | * [[Newport 835]] power meter | ||
+ | |||
+ | * [[HP 438A]] power meter | ||
+ | |||
+ | * [[Thorlabs 1.2GHz Biased PD]] | ||
+ | |||
+ | * [[u2t High Speed PDs]] | ||
+ | |||
+ | == Misc. characterization == | ||
+ | * [[Wm100 omega meter]] | ||
+ | * [[FR-103MN Femtochrome Autocorrelator]] | ||
+ | * [[5-14B Autocorrelator]] | ||
+ | |||
+ | == Cameras == | ||
+ | * [[Goodrich KTS]] | ||
+ | |||
+ | * [[Hamamatsu streak camera]] (parts in trailer) | ||
+ | |||
+ | * [[FLIR TAU 640]] | ||
== Optical sources == | == Optical sources == | ||
=== Broadband sources === | === Broadband sources === | ||
− | * | + | * [[INPHENIX IPSDS1003 1050nm SLD]] |
+ | |||
+ | * ASE source | ||
+ | |||
+ | Agilent broadband ASE source - [[Media:Spectrum.jpg|Spectrum]] | ||
+ | |||
+ | * Hg lamp | ||
+ | |||
=== CW lasers === | === CW lasers === | ||
− | * | + | |
+ | ==== 1550 nm==== | ||
+ | * [[RIO Lasers]] 1kHz linewidth DBR lasers, 20mW, 1565nm | ||
+ | |||
+ | * [[Orbits Ethernal]] fiber lasers (3), all around 1537 nm | ||
+ | |||
+ | * [[Koheras Boostik]] fiber laser | ||
+ | |||
+ | * [[Koshin LS-601A]] tunable laser | ||
+ | |||
+ | ==== 1310 nm==== | ||
* [[Emcore 1614W]] (2): 1310nm | * [[Emcore 1614W]] (2): 1310nm | ||
+ | |||
+ | * [[Lightwave Electronics 120-04]] (2): 1319nm | ||
+ | |||
+ | ==== 780, 1060, 1300 nm ==== | ||
+ | * [[Thorlabs Tunable Laser Kits]] | ||
+ | |||
+ | ==== Other ==== | ||
+ | * [[SDL-8610]] (2): 850nm, 100mW, fiber-coupled | ||
+ | |||
=== Pulsed lasers === | === Pulsed lasers === | ||
− | * Calmar mode-locked laser ( | + | * [[Calmar mode-locked laser]] |
+ | |||
+ | * [[PriTel PFL-1550]] femtosecond mode-locked laser | ||
+ | |||
+ | == Amplifiers == | ||
+ | * [[Calmar L-band EDFA]] | ||
+ | |||
+ | * [[INPHENIX SOA]] | ||
+ | |||
+ | * [[IPG EAD-2K-C]] C-band EDFA with 33dBm max. output power | ||
+ | |||
+ | * [[IPG EAR-2K-C]] (2) C-band EDFA with 33dBm max. output power | ||
+ | |||
+ | * [[MPB EFA-P21F]] C-band gain-flattened EDFA wtih 21 dBm max. output power | ||
+ | |||
+ | * [[Thorlabs 1132P BOA]] O-band (1300nm) booster SOA with ~17 dBm max. output power | ||
+ | |||
+ | == Attenuators == | ||
+ | * [[Agilent 81577A]] (2) high-power attenuator | ||
+ | |||
+ | * [[HP8156A]] (at least 2) | ||
+ | |||
+ | * [[NetTest attenuator]] | ||
+ | |||
+ | == Modulators/transmitters == | ||
+ | === High-speed === | ||
+ | *[[SHF 4003A]] 40Gb/s transmitter | ||
+ | |||
+ | *[[JDSU 10024180]] intensity modulator | ||
+ | |||
+ | *[[Sumitomo T.MZH1.5-40X-ADC-Y-Z]] intensity mod (40G) | ||
+ | |||
+ | === Low-speed === | ||
+ | * [[Brimrose AOM]] Acousto-optic modulator | ||
+ | |||
+ | *[[IntraAction ME]] AOM driver | ||
+ | |||
+ | * [[Oriel chopper]] Chopper + controller | ||
+ | |||
+ | * [[SR540 chopper]] and controller | ||
= Other = | = Other = | ||
+ | == Polisher == | ||
+ | |||
+ | [http://iac.princeton.edu/manuals/Instructions%20for%20Allied%20Multiprep%20System.pdf Polisher Instruction Manual] | ||
+ | |||
+ | == Communication == | ||
+ | |||
+ | We have several USB/GPIB converters. The one from Agilent is not intuitive to install. Follow the instructions here:[[Agilent 82357A (USB/GPIB)]] | ||
+ | |||
+ | * [http://sine.ni.com/nips/cds/view/p/lang/en/nid/201586 NI GPIB-USB-HS] | ||
+ | |||
+ | * [[Black Box]] RS232/GPIB converter | ||
+ | |||
== Opto-mechanics == | == Opto-mechanics == | ||
+ | * [[Newport 855C]] programmable controller (for up to 4 mechanical actuators) | ||
+ | |||
== Water coolers == | == Water coolers == | ||
== Optical tables == | == Optical tables == | ||
Line 46: | Line 351: | ||
First aid kit (near fume hood) | First aid kit (near fume hood) | ||
− | Radiation [[safety goggles]] at various wavelengths (in bin above sample cabinet) | + | Fire extinguisher near the main entrance |
+ | |||
+ | Shower and eye-wash in the hallway right outside the lab | ||
+ | |||
+ | Radiation [[safety goggles]] at various wavelengths (in bin above sample cabinet). Check the UCSB [http://www.ehs.ucsb.edu/units/rad/radrsc/radsaftypdfs/lasersaftyman.pdf laser safety manual] for guidelines on choosing appropriate goggles for your experiment. | ||
+ | |||
+ | |||
+ | Safety documents: | ||
+ | |||
+ | [[Fume Hood|Click here]] for a list of chemicals in the fume hood and links to their MSDSs. | ||
+ | |||
+ | Lab-specific guidelines: [[File:FemtolabCHPSecI.pdf]] | ||
+ | |||
+ | Campus-wide chemical hygiene plan Section II (UCSB policies, procedures, and resources): | ||
+ | |||
+ | * CURRENT: [http://ehs.ucsb.edu/units/labsfty/labrsc/chemistry/CHP%20Pages/Sec.II.2013.pdf EH&S online version] | ||
+ | * OLD: [[File:CampuswideCHPSec.II.2011.pdf]] | ||
+ | |||
+ | Campus-wide chemical hygiene plan Section III (regulatory framework): | ||
+ | * CURRENT: [http://www.ehs.ucsb.edu/units/labsfty/labrsc/manuals/section_III.pdf EH&S online version] | ||
+ | * OLD: [[File: CampuswideCHPsection_III.2011.pdf]] |
Latest revision as of 16:03, 2 February 2016
Equipment that has been checked out of the lab: doc.
Equipment that is stored in the trailer: Equipment_in_trailer. Updated 03/04/13
Equipment that is stored in the third floor office. Check here for spare computer parts: docx.
Contents
Electrical[edit]
Microwave[edit]
Electrical spectrum analyzers[edit]
- HP 70000 (2) - these have an optical input port as well. They need to be installed in a mainframe.
RF signal generators[edit]
- Fluke 6060 (2)
- HP 8340B synthesized sweep generator (10 MHz to 26.5 GHz)
Data Tx/Rx[edit]
- Quantum DD1 divider delay unit
Amplifiers[edit]
- HP 8349B (2-20GHz)
- EIN 300L (kHz-110MHz)
Network analyzers[edit]
- HP 8703A (lightwave component analyzer)
- Agilent E8364A (PNA with LCA attachment)
- PNA-X HP N52454A (10MHz - 50GHz)
- We also have an HP 8510A (45MHz - 26.5 GHz) that has been donated to the microwave teaching lab in HFH.
RF Filters[edit]
- Variety available from K&L Microwave, Inc.
RF Components[edit]
C-V meters[edit]
Data acquisition and switching[edit]
- Hameg_8123
- Agilent 34980A with microwave and general purpose switching modules
- Monochrome Image Capture Card
Cables & connectors[edit]
- See the attached document for instructions on microwave connector care.
Probes[edit]
RF probes and their latest calibration files:
GSG 100:
- 40GHz S/N 96265: File:ACP40 GSG100 96265.txt
Other[edit]
- HP 70820A microwave transition analyzer (essentially an oscilloscope with excellent rise-time measuring capabilities)
DC[edit]
Voltage/current sources[edit]
- Keithley 2400 series source meters
- Keithley 2600 series source meters
- ILX LDP 3811 pulsed current source
- ILX LDX-3207B laser diode driver
- LDX-3220 laser diode driver
- Light Control Instruments 502 laser diode driver
- SDL-8610-D laser diode driver (for SDL-8610 850 nm lasers)
- ILX FOA-8100 fiber amplifier driver
- LCI-102 current source
- New Focus 0901 current source
- Agilent E3640 DC voltage source
- HP 6205C dual DC voltage source
- Kikusui PAB 18-3 DC voltage source
- Lambda LA-200 DC voltage source
- LDC9003A DC voltage source
- Bertran 215 High-voltage DC source
Multimeters[edit]
- HP 4338B milliohm-meter
- Keithley 6485 picoammeter
- Keithley 485 picoammeter
- Fluke 8012A multi-meter
- HP 3468B multi-meter
- HP 3478A multi-meter
- Keithley 175 multi-meter
Semiconductor parameter analyzers[edit]
- HP 4145A Semiconductor parameter analyzer
Temperature controllers[edit]
AC[edit]
Oscilloscopes[edit]
- Hitachi V-355 oscilloscope
- Tek 11801 digital sampling scope
- Tek 5104B oscilloscope
- Lecroy SDA 100G oscilloscope
Pulse generators[edit]
- Agilent 33250A Function generator to 80MHz
- HP 8116A (2) function generators to 50MHz
- PulseBlasterDDS (2) PCI board to generate pulses with 100MHz clock
Lock-in amplifiers[edit]
Other amplifiers[edit]
- SR570 current pre-amplifier
Optical[edit]
OSAs[edit]
Fiber optics[edit]
OADM Filter[edit]
- OPLink OADMG2C34000214 (>4) 1549.87~1550.37nm
Tunable filters[edit]
- JDSU TB4500 (2) 1535-1565 nm, F-P type
- Koshin FC-1560B-1-1 (1) 1540-1560 nm (2 filters, 1 housing)
- Santec OTF (4) 1535-1565 nm, various bandwidths, probably membrane
- Agiltron FOTF-023121333 (1) 1270-1345 nm, 1nm 3dB bandwidth, IL = 2.1~2.8dB, probably membrane
Isolators[edit]
Polarizers[edit]
- OZopticsPolarizers Polarizers from OZ optics
Polarization beam splitters[edit]
- 9/125-SPP-1550-PBS-50-3A3U3U: from "ozoptics", one SMF in (APC)/two PMF (UPC) out; 50 dB reflection;
Switches[edit]
- HP 86060C lightwave switch
Fiber Spools[edit]
Detectors[edit]
High-speed Measurement[edit]
- Agilent LCA N4373A Lightwave component analyzer (DC - 67 GHz) - attached to the Agilent E8364A
- Agilent LCA xxx Lightwave component analyzer (DC - 26.5GHz)
Power meters/broad area PDs[edit]
- Newport 835 power meter
- HP 438A power meter
Misc. characterization[edit]
Cameras[edit]
- Hamamatsu streak camera (parts in trailer)
Optical sources[edit]
Broadband sources[edit]
- ASE source
Agilent broadband ASE source - Spectrum
- Hg lamp
CW lasers[edit]
1550 nm[edit]
- RIO Lasers 1kHz linewidth DBR lasers, 20mW, 1565nm
- Orbits Ethernal fiber lasers (3), all around 1537 nm
- Koheras Boostik fiber laser
- Koshin LS-601A tunable laser
1310 nm[edit]
- Emcore 1614W (2): 1310nm
- Lightwave Electronics 120-04 (2): 1319nm
780, 1060, 1300 nm[edit]
Other[edit]
- SDL-8610 (2): 850nm, 100mW, fiber-coupled
Pulsed lasers[edit]
- PriTel PFL-1550 femtosecond mode-locked laser
Amplifiers[edit]
- IPG EAD-2K-C C-band EDFA with 33dBm max. output power
- IPG EAR-2K-C (2) C-band EDFA with 33dBm max. output power
- MPB EFA-P21F C-band gain-flattened EDFA wtih 21 dBm max. output power
- Thorlabs 1132P BOA O-band (1300nm) booster SOA with ~17 dBm max. output power
Attenuators[edit]
- Agilent 81577A (2) high-power attenuator
- HP8156A (at least 2)
Modulators/transmitters[edit]
High-speed[edit]
- SHF 4003A 40Gb/s transmitter
- JDSU 10024180 intensity modulator
- Sumitomo T.MZH1.5-40X-ADC-Y-Z intensity mod (40G)
Low-speed[edit]
- Brimrose AOM Acousto-optic modulator
- IntraAction ME AOM driver
- Oriel chopper Chopper + controller
- SR540 chopper and controller
Other[edit]
Polisher[edit]
Communication[edit]
We have several USB/GPIB converters. The one from Agilent is not intuitive to install. Follow the instructions here:Agilent 82357A (USB/GPIB)
- Black Box RS232/GPIB converter
Opto-mechanics[edit]
- Newport 855C programmable controller (for up to 4 mechanical actuators)
Water coolers[edit]
Optical tables[edit]
Safety[edit]
First aid kit (near fume hood)
Fire extinguisher near the main entrance
Shower and eye-wash in the hallway right outside the lab
Radiation safety goggles at various wavelengths (in bin above sample cabinet). Check the UCSB laser safety manual for guidelines on choosing appropriate goggles for your experiment.
Safety documents:
Click here for a list of chemicals in the fume hood and links to their MSDSs.
Lab-specific guidelines: File:FemtolabCHPSecI.pdf
Campus-wide chemical hygiene plan Section II (UCSB policies, procedures, and resources):
- CURRENT: EH&S online version
- OLD: File:CampuswideCHPSec.II.2011.pdf
Campus-wide chemical hygiene plan Section III (regulatory framework):
- CURRENT: EH&S online version
- OLD: File:CampuswideCHPsection III.2011.pdf