Difference between revisions of "Equipment"

From OptoelectronicsWiki
Jump to: navigation, search
(1550 nm)
 
(29 intermediate revisions by 8 users not shown)
Line 3: Line 3:
 
Equipment that has been checked out of the lab: [[Media:Check_out_list.doc‎|doc]].
 
Equipment that has been checked out of the lab: [[Media:Check_out_list.doc‎|doc]].
  
Equipment that is stored in the trailer: [[Media:Equipment_intrailer_updated_6-13_by_mike.docx|docx]]. Updated 6/13/12
+
Equipment that is stored in the trailer: [[Media:Equipment_in_trailer_updated_05-31-2013_by_Stanton.docx|Equipment_in_trailer]]. Updated 03/04/13
  
 
Equipment that is stored in the third floor office.  Check here for spare computer parts: [[Media:Equipment_upstairsoffice.docx|docx]].
 
Equipment that is stored in the third floor office.  Check here for spare computer parts: [[Media:Equipment_upstairsoffice.docx|docx]].
Line 67: Line 67:
  
 
* [[HP 4284A]]
 
* [[HP 4284A]]
 +
 +
=== Data acquisition and switching ===
 +
* [[Hameg_8123]]
 +
* [[Agilent 34980A]] with microwave and general purpose switching modules
 +
* [[Monochrome Image Capture Card]]
  
 
=== Cables & connectors ===
 
=== Cables & connectors ===
  
 
* See the attached [[Media:Connectors.docx|document]] for instructions on microwave connector care.
 
* See the attached [[Media:Connectors.docx|document]] for instructions on microwave connector care.
 +
 +
=== Probes ===
 +
 +
RF probes and their latest calibration files:
 +
 +
GSG 100:
 +
 +
* 40GHz S/N 96265: [[File:ACP40_GSG100_96265.txt]]
  
 
=== Other ===
 
=== Other ===
Line 158: Line 171:
  
 
* [[Tek 5104B]] oscilloscope
 
* [[Tek 5104B]] oscilloscope
 +
 +
* [[Lecroy SDA 100G]] oscilloscope
  
 
=== Pulse generators ===
 
=== Pulse generators ===
Line 165: Line 180:
  
 
*[[HP 214B]]
 
*[[HP 214B]]
 +
 +
*[[PulseBlasterDDS]] (2) PCI board to generate pulses with 100MHz clock
  
 
=== Lock-in amplifiers ===
 
=== Lock-in amplifiers ===
Line 176: Line 193:
 
= Optical =
 
= Optical =
 
== OSAs ==
 
== OSAs ==
* [[HP 71451A]]
+
* [[HP 70951A]]
  
 
* [[Agilent 86142B]]
 
* [[Agilent 86142B]]
 +
 +
* [[Yokogawa AQ6370C-1]]
 +
 +
* [[SPEX 500M]]
  
 
== Fiber optics ==
 
== Fiber optics ==
Line 203: Line 224:
 
=== Switches ===
 
=== Switches ===
 
* [[HP 86060C]] lightwave switch
 
* [[HP 86060C]] lightwave switch
 +
 +
=== Fiber Spools ===
 +
* [[Media:FiberSpoolsOTDR.zip]]
  
 
== Detectors ==
 
== Detectors ==
Line 222: Line 246:
 
== Misc. characterization ==
 
== Misc. characterization ==
 
* [[Wm100 omega meter]]
 
* [[Wm100 omega meter]]
 +
* [[FR-103MN Femtochrome Autocorrelator]]
 
* [[5-14B Autocorrelator]]
 
* [[5-14B Autocorrelator]]
  
Line 233: Line 258:
 
== Optical sources ==
 
== Optical sources ==
 
=== Broadband sources ===
 
=== Broadband sources ===
* SLED (example)
+
* [[INPHENIX IPSDS1003 1050nm SLD]]
  
 
* ASE source
 
* ASE source
 +
 +
Agilent broadband ASE source - [[Media:Spectrum.jpg|Spectrum]]
  
 
* Hg lamp
 
* Hg lamp
Line 242: Line 269:
  
 
==== 1550 nm====
 
==== 1550 nm====
* Agilent TLS (example)
+
* [[RIO Lasers]] 1kHz linewidth DBR lasers, 20mW, 1565nm
  
 
* [[Orbits Ethernal]] fiber lasers (3), all around 1537 nm
 
* [[Orbits Ethernal]] fiber lasers (3), all around 1537 nm
  
 
* [[Koheras Boostik]] fiber laser
 
* [[Koheras Boostik]] fiber laser
 +
 +
* [[Koshin LS-601A]] tunable laser
  
 
==== 1310 nm====
 
==== 1310 nm====
Line 266: Line 295:
 
== Amplifiers ==
 
== Amplifiers ==
 
* [[Calmar L-band EDFA]]
 
* [[Calmar L-band EDFA]]
 +
 +
* [[INPHENIX SOA]]
  
 
* [[IPG EAD-2K-C]] C-band EDFA with 33dBm max. output power
 
* [[IPG EAD-2K-C]] C-band EDFA with 33dBm max. output power
Line 287: Line 318:
  
 
*[[JDSU 10024180]] intensity modulator
 
*[[JDSU 10024180]] intensity modulator
 +
 +
*[[Sumitomo T.MZH1.5-40X-ADC-Y-Z]] intensity mod (40G)
  
 
=== Low-speed ===
 
=== Low-speed ===
Line 298: Line 331:
  
 
= Other =
 
= Other =
 +
== Polisher ==
 +
 +
[http://iac.princeton.edu/manuals/Instructions%20for%20Allied%20Multiprep%20System.pdf Polisher Instruction Manual]
 +
 
== Communication ==
 
== Communication ==
  
 
We have several USB/GPIB converters.  The one from Agilent is not intuitive to install. Follow the instructions here:[[Agilent 82357A (USB/GPIB)]]
 
We have several USB/GPIB converters.  The one from Agilent is not intuitive to install. Follow the instructions here:[[Agilent 82357A (USB/GPIB)]]
 +
 +
* [http://sine.ni.com/nips/cds/view/p/lang/en/nid/201586 NI GPIB-USB-HS]
  
 
* [[Black Box]] RS232/GPIB converter
 
* [[Black Box]] RS232/GPIB converter
Line 325: Line 364:
 
Lab-specific guidelines: [[File:FemtolabCHPSecI.pdf]]
 
Lab-specific guidelines: [[File:FemtolabCHPSecI.pdf]]
  
Campus-wide chemical hygiene plan Section II (UCSB policies, procedures, and resources): [[File:CampuswideCHPSec.II.2011.pdf]]
+
Campus-wide chemical hygiene plan Section II (UCSB policies, procedures, and resources):
 +
 
 +
* CURRENT: [http://ehs.ucsb.edu/units/labsfty/labrsc/chemistry/CHP%20Pages/Sec.II.2013.pdf EH&S online version]
 +
* OLD: [[File:CampuswideCHPSec.II.2011.pdf]]
  
Campus-wide chemical hygiene plan Section III (regulatory framework): [[File: CampuswideCHPsection_III.2011.pdf]]
+
Campus-wide chemical hygiene plan Section III (regulatory framework):
 +
* CURRENT: [http://www.ehs.ucsb.edu/units/labsfty/labrsc/manuals/section_III.pdf EH&S online version]
 +
* OLD: [[File: CampuswideCHPsection_III.2011.pdf]]

Latest revision as of 16:03, 2 February 2016

Equipment wish list

Equipment that has been checked out of the lab: doc.

Equipment that is stored in the trailer: Equipment_in_trailer. Updated 03/04/13

Equipment that is stored in the third floor office. Check here for spare computer parts: docx.

Electrical[edit]

Microwave[edit]

Electrical spectrum analyzers[edit]

  • HP 70000 (2) - these have an optical input port as well. They need to be installed in a mainframe.

RF signal generators[edit]

  • HP 8340B synthesized sweep generator (10 MHz to 26.5 GHz)

Data Tx/Rx[edit]

Amplifiers[edit]

Network analyzers[edit]

  • HP 8703A (lightwave component analyzer)
  • We also have an HP 8510A (45MHz - 26.5 GHz) that has been donated to the microwave teaching lab in HFH.

RF Filters[edit]

  • Variety available from K&L Microwave, Inc.

RF Components[edit]

C-V meters[edit]

Data acquisition and switching[edit]

Cables & connectors[edit]

  • See the attached document for instructions on microwave connector care.

Probes[edit]

RF probes and their latest calibration files:

GSG 100:

Other[edit]

  • HP 70820A microwave transition analyzer (essentially an oscilloscope with excellent rise-time measuring capabilities)

DC[edit]

Voltage/current sources[edit]

Multimeters[edit]

Semiconductor parameter analyzers[edit]

  • HP 4145A Semiconductor parameter analyzer


Temperature controllers[edit]


AC[edit]

Oscilloscopes[edit]

Pulse generators[edit]

  • HP 8116A (2) function generators to 50MHz

Lock-in amplifiers[edit]

Other amplifiers[edit]

  • SR570 current pre-amplifier

Optical[edit]

OSAs[edit]

Fiber optics[edit]

OADM Filter[edit]

Tunable filters[edit]

  • Santec OTF (4) 1535-1565 nm, various bandwidths, probably membrane

Isolators[edit]

Polarizers[edit]

Polarization beam splitters[edit]

  • 9/125-SPP-1550-PBS-50-3A3U3U: from "ozoptics", one SMF in (APC)/two PMF (UPC) out; 50 dB reflection;

Switches[edit]

Fiber Spools[edit]

Detectors[edit]

High-speed Measurement[edit]

Power meters/broad area PDs[edit]

Misc. characterization[edit]

Cameras[edit]

Optical sources[edit]

Broadband sources[edit]

  • ASE source

Agilent broadband ASE source - Spectrum

  • Hg lamp

CW lasers[edit]

1550 nm[edit]

  • RIO Lasers 1kHz linewidth DBR lasers, 20mW, 1565nm

1310 nm[edit]

780, 1060, 1300 nm[edit]

Other[edit]

  • SDL-8610 (2): 850nm, 100mW, fiber-coupled

Pulsed lasers[edit]

Amplifiers[edit]

  • MPB EFA-P21F C-band gain-flattened EDFA wtih 21 dBm max. output power

Attenuators[edit]

Modulators/transmitters[edit]

High-speed[edit]

Low-speed[edit]

Other[edit]

Polisher[edit]

Polisher Instruction Manual

Communication[edit]

We have several USB/GPIB converters. The one from Agilent is not intuitive to install. Follow the instructions here:Agilent 82357A (USB/GPIB)

Opto-mechanics[edit]

  • Newport 855C programmable controller (for up to 4 mechanical actuators)

Water coolers[edit]

Optical tables[edit]

Safety[edit]

First aid kit (near fume hood)

Fire extinguisher near the main entrance

Shower and eye-wash in the hallway right outside the lab

Radiation safety goggles at various wavelengths (in bin above sample cabinet). Check the UCSB laser safety manual for guidelines on choosing appropriate goggles for your experiment.


Safety documents:

Click here for a list of chemicals in the fume hood and links to their MSDSs.

Lab-specific guidelines: File:FemtolabCHPSecI.pdf

Campus-wide chemical hygiene plan Section II (UCSB policies, procedures, and resources):

Campus-wide chemical hygiene plan Section III (regulatory framework):