Difference between revisions of "DesignRules"

From OptoelectronicsWiki
Jump to: navigation, search
Line 37: Line 37:
 
* With circular pads, it is difficult to lift-off small rings (<5 microns)
 
* With circular pads, it is difficult to lift-off small rings (<5 microns)
 
Keep radius between 30-60 microns.
 
Keep radius between 30-60 microns.
 +
 +
* Also, it is good to have a set of PTLMs that will be exposed to implantation step. This would be a way to check if the
 +
implantation was effective. Resistance between pads with implantation must be hundred or kilo ohms or larger.
  
 
Document with figures to follow soon for further details.
 
Document with figures to follow soon for further details.

Revision as of 14:06, 30 April 2010

Design Rules

WG

  • 3 um trenches for 200 um S-bends keep bending losses minimal
  • Put 50 um trench around Verniers and alignment markers

VC

  • 10 um x 10 um, 50 um separation
  • No VC around verniers, so verviers have a chance of being exposed after substrate removal

Mesa

  • 14 um wide

QW

  • 16 um wide

Thick p metal

  • Same at N metal
  • 4 um wide
  • Keep 11 um separation between thick P and N metal.

N Metal

  • 20 um wide

Implant

  • 12 um wide
  • Implant after anneal to ensure the quality

Via

  • Min. 6 um opening
  • Open up area that is uniform at bottom


Square/Circular TLM patterns design rules

  • Distance between adjacent pads - 4 to 30 microns in 5 or more steps.

Smaller the distance, more accurate the estimate.

  • Pad width/diameter must be atleast 2x the max distance between pads.

Eg. Say if you have 6 pads with 5,8,12,15,20 micron spacing, it is recommended that the pad be > (2x20) microns wide

  • Rectangular/square pads will need to be etched on the outer sides for isolation. That is not the case with circular pads.
  • With circular pads, it is difficult to lift-off small rings (<5 microns)

Keep radius between 30-60 microns.

  • Also, it is good to have a set of PTLMs that will be exposed to implantation step. This would be a way to check if the

implantation was effective. Resistance between pads with implantation must be hundred or kilo ohms or larger.

Document with figures to follow soon for further details.



Processing Rules

Always put a dummy/witness sample in the chamber when depositing metals and dielectrics.

  • Samples can later be used for determining thicknesses.
  • These samples can also be used if a given layer has to be etched on the real sample, but etch is not well characterized.