Name | Thumbnail | Size | User | Description | Versions |
---|---|---|---|---|---|---|
14:46, 18 January 2011 | HP4284A CV.m (file) | ![]() |
2 KB | Molly | Takes a C-V measurement on the HP4284A in matlab | 1 |
15:51, 19 November 2010 | SiO2 Vert.pdf (file) | ![]() |
70 KB | Molly | ICP2 etch rate of PECVD SiO2 using recipe 101 SiOxVert (CHF3) | 1 |
15:03, 20 July 2010 | Specs.jpg (file) | ![]() |
239 KB | Molly | Calmar L-band EDFA specs | 1 |
14:54, 20 July 2010 | Characterization of AMP STL20 Driving currents.PDF (file) | ![]() |
19 KB | Molly | Noise figure as a function of drive current for the Calmar L-band EDFA | 1 |
14:53, 20 July 2010 | Characterization of AMP STL20 Wavelengths.PDF (file) | ![]() |
18 KB | Molly | Output power and noise figure as a function of wavelength for the Calmar L-band EDFA (-5dBm input power, maximum gain) | 1 |
14:52, 20 July 2010 | Characterization of AMP STL20.PDF (file) | ![]() |
30 KB | Molly | Maximum output power as a function of input power (and associated noise figures) for the Calmar L-band EDFA | 1 |
14:47, 20 July 2010 | Specifications.PDF (file) | ![]() |
25 KB | Molly | Specs of the Calmar L-band EDFA | 1 |
14:47, 20 July 2010 | Principle of Operation.PDF (file) | ![]() |
24 KB | Molly | Principle of operation of the Calmar L-band EDFA | 1 |
14:46, 20 July 2010 | Table of Contents.PDF (file) | ![]() |
39 KB | Molly | Table of contents for the L-band EDFA manual | 1 |
11:03, 12 May 2010 | Bowers Contact Sheet 4-10.pdf (file) | ![]() |
197 KB | Molly | group contact sheet in PDF form as of 4/10 | 1 |
12:23, 11 May 2010 | SRIM implant.zip (file) | ![]() |
12.03 MB | Molly | Installation files for SRIM - the stopping and range of ions in matter | 1 |
17:46, 4 May 2010 | AgilentE8257D datasheet.pdf (file) | ![]() |
1.67 MB | Molly | Datasheet for Agilent E8257D (signal generator) | 1 |
17:43, 4 May 2010 | Better Measurements Using RF Signal Generators.pdf (file) | ![]() |
959 KB | Molly | Agilent RF signal generator manual | 1 |
17:41, 4 May 2010 | HP 8673Series Datasheet.pdf (file) | ![]() |
226 KB | Molly | HP 8673D (signal generator) datasheet | 1 |
15:22, 29 April 2010 | Emcore testfixture.jpg (file) | ![]() |
275 KB | Molly | PCB layout for Emcore 1614W and 1772 lasers | 1 |
15:18, 29 April 2010 | Fixture Connection.doc (file) | ![]() |
562 KB | Molly | Schematic for Emcore 1614W and 1772 laser modules | 1 |
15:12, 29 April 2010 | 1614Wdatasheet.pdf (file) | ![]() |
607 KB | Molly | Datasheet for Emcore 1614W DFBs | 1 |
10:04, 7 April 2010 | Cond consts gpsIII IV V.pdf (file) | ![]() |
168 KB | Molly | Thermal conductivities of semiconductors | 1 |
14:30, 5 April 2010 | COMSOL drawingscreenshot.png (file) | ![]() |
58 KB | Molly | 1 | |
13:53, 5 April 2010 | Comsol license.txt (file) | ![]() |
833 B | Molly | 1 | |
11:35, 15 March 2010 | Fl6060x sig gen.zip (file) | ![]() |
368 KB | Molly | Labview vi library for Fluke 6060 signal generators | 1 |
11:17, 15 March 2010 | 5989-9815EN.pdf (file) | ![]() |
193 KB | Molly | Agilent E4407B spectrum analyzer datasheet | 1 |
11:15, 15 March 2010 | E4407B spectrum Read.vi (file) | ![]() |
382 KB | Molly | Reads the spectrum from the Agilent E4407B | 1 |
11:08, 15 March 2010 | AN MATLABandFSU.pdf (file) | ![]() |
267 KB | Molly | 1 | |
11:07, 15 March 2010 | FSU datasheet.pdf (file) | ![]() |
330 KB | Molly | Rohde & Schwarz spectrum analyzer datasheet | 1 |
19:46, 5 March 2010 | FSU OpMa en.pdf (file) | ![]() |
7.18 MB | Molly | Rohde & Schwarz FSU operating manual | 1 |
18:50, 5 March 2010 | SensitiveOIP3.m (file) | ![]() |
5 KB | Molly | Takes the 2-tone OIP3. The values it gives for OIP3 aren't exact, just ballpark. | 1 |
18:49, 5 March 2010 | SensitiveOIP2.m (file) | ![]() |
5 KB | Molly | Takes the 2-tone OIP2. The numbers it gives for OIP2 aren't exact, just ballpark. | 1 |
18:38, 5 March 2010 | SigGen setlevel.m (file) | ![]() |
605 B | Molly | This function sets the output power level and turns on the synthesizer | 1 |
18:38, 5 March 2010 | SigGen init.m (file) | ![]() |
724 B | Molly | This function resets the Signal generator to its default instrument values (-30dBm (output power) and 1000MHz (frequency) and then sets the input frequency | 1 |
18:37, 5 March 2010 | Respo AgilentKeithley.m (file) | ![]() |
3 KB | Molly | Gets responsivity curve from Agilent attenuator and Keithley source meter | 1 |
18:31, 5 March 2010 | P1dB.m (file) | ![]() |
2 KB | Molly | Measures the 1-dB compression current and power using an Agilent attenuator and R&S spectrum analyzer. Requires sensitiveReadSpectrum.m. | 1 |